RevA MN301200 7of10
INSTALLATION StepFive
The basic operating principle of the sump float is very simple.As fluid level rises the float will also rise,
resulting in a tilt of the microswitch located inside the housing.This tilt will generate a signal that can be
used to actuate a motor or signal anindicator alarm.To ensure theproper function of the sump float, it is
necessarytosecuretheelectriccableinsidethetankorwell.Thelengthofthecablemeasuredbetweenthe
fixturepoint(seebelow)andthebodyofthefloatdeterminesthetotalextensionofthefloat.Thisresultsin
thedistancebetweenthepumpstoppingandstartinglevel.Thisdistanceshouldbenolessthan6in(15cm).
Itisessentialtoensurethattherearenoobstructionsinthesumpfloatsoperationalareabeforeoperation.
Warning:During operation, adjustments to the sump float cable must not be made under any
circumstances due to the fact that any unwanted cable connections made while the sump float is
immersedinwatercanleadtoelectricshock.
There are two installation options for this sump float.One method is to fix the cable of the float to the
reservoir or container with the use of a small clamp.Another technique would be to attachthe LV497000
counterweighttothefloat’scableadesireddistancebetweenthehighestandlowestleveldesired.
Note:Withtheuseofthecounterweight,thelengthofcablebetweenthefloatandfixedpoint(starting
andstoppingindication)canbefreelyadjusted.
Note: The LV42 series is self counterweighted and can be used without the need of additional
counterweight,clamp,orbracket.Thepreviousaremeanstosimplifyinstallationandaidinorganizingthe
useofmultiplefloatswitches.
FillOperation‐ShownwithCounterWeight EmptyOperation‐ShownwithCounterWeight
INSTALLATIONOFCOUNTERWEIGHT
Forcorrectcounterweightinstallation,refertothefollowingprocedureaswellastheillustration.
1. Insert the cable into the counterweight, turning it.This will
result in the detachment of the plastic ring inserted in the
mouth (if necessary use a screwdriver to aid in the
detachment of
the ring).Place the ring at the point on the
cablewherethecounterweightistobeattached.
2. Attach the counterweight on the ring by turning it and using
moderatepressure.(Counterweightsoldseparately).
